AVA5-50FX

AVA5-50FX, HELIAX® Andrew Virtual Air Coaxial Cable, corrugated copper, 7/8 in, black PE jacket (Halogen free jacketing non-fire-retardant)

Technical Specifications

Specifications

Product classification

Product TypeCoaxial wireless cable
Product BrandHELIAX®
Product SeriesAVA5-50FX
Ordering NoteANDREW® non-standard product | Not available in the United States or Canada

General specifications

Product Number520096403/00 | SZ520096403/00
FlexibilityStandard
Jacket ColorBlack
Performance NoteAttenuation values typical, guaranteed within 5%

Dimensions

Diameter Over Dielectric24.13 mm | 0.95 in
Diameter Over Jacket27.991 mm | 1.102 in
Inner Conductor OD9.4488 mm | 0.372 in
Outer Conductor OD25.4 mm | 1 in
Nominal Size7/8 in

Electrical specifications

Cable Impedance50 ohm ±1 ohm
Capacitance73 pF/m | 22.25 pF/ft
dc Resistance, Inner Conductor3.1 ohms/km | 0.945 ohms/kft
dc Resistance, Outer Conductor1.53 ohms/km | 0.466 ohms/kft
dc Test Voltage6000 V
Inductance0.184 µH/m | 0.056 µH/ft
Insulation Resistance100000 MOhms-km
Jacket Spark Test Voltage (rms)8000 V
Operating Frequency Band1 – 5000 MHz
Peak Power91 kW
Velocity90 %

Attenuation

 
 
 

Attenuation

FrequencyAttenuation (db/100 m)Attenuation (db/100 ft)Average power (kw)
1.0 MHz0.1130.03474.43
1.5 MHz0.1380.04260.73
2.0 MHz0.1600.04952.56
10.0 MHz0.3590.11023.37
20.0 MHz0.5100.15616.46
30.0 MHz0.6270.19113.39
50.0 MHz0.8140.24810.32
85.0 MHz1.0680.3267.86
88.0 MHz1.0880.3327.72
100.0 MHz1.1620.3547.23
108.0 MHz1.2090.3686.95
150.0 MHz1.4330.4375.86
174.0 MHz1.5480.4725.43
200.0 MHz1.6650.5075.05
204.0 MHz1.6820.5134.99
300.0 MHz2.0590.6284.08
400.0 MHz2.3980.7313.50
450.0 MHz2.5530.7783.29
460.0 MHz2.5830.7873.25
500.0 MHz2.7000.8233.11
512.0 MHz2.7350.8343.07
600.0 MHz2.9770.9072.82
700.0 MHz3.2350.9862.60
800.0 MHz3.4781.0602.42
824.0 MHz3.5341.0772.38
894.0 MHz3.6941.1262.27
960.0 MHz3.8411.1712.19
1000.0 MHz3.9271.1972.14
1218.0 MHz4.3771.3341.92
1250.0 MHz4.4401.3531.89
1500.0 MHz4.9121.4971.71
1700.0 MHz5.2681.6051.59
1794.0 MHz5.4291.6551.55
1800.0 MHz5.4391.6581.54
2000.0 MHz5.7711.7591.46
2100.0 MHz5.9331.8081.42
2200.0 MHz6.0911.8561.38
2300.0 MHz6.2471.9041.34
2500.0 MHz6.5501.9961.28
2700.0 MHz6.8452.0861.23
3000.0 MHz7.2722.2171.15
3400.0 MHz7.8192.3831.07
3600.0 MHz8.0832.4641.04
3700.0 MHz8.2132.5031.02
3800.0 MHz8.3422.5421.01
3900.0 MHz8.4702.5810.99
4000.0 MHz8.5962.6200.98
4100.0 MHz8.7222.6580.96
4200.0 MHz8.8462.6960.95
4300.0 MHz8.9692.7340.94
4400.0 MHz9.0922.7710.92
4500.0 MHz9.2132.8080.91
4600.0 MHz9.3332.8450.90
4700.0 MHz9.4532.8810.89
4800.0 MHz9.5722.9170.88
4900.0 MHz9.6892.9530.87
5000.0 MHz9.8062.9890.86

Return loss/vswr

Frequency bandVswrReturn loss (db)
680–800 MHz1.13024.30
800–960 MHz1.13024.30
1700–2200 MHz1.13024.30

Material specifications

Dielectric MaterialFoam PE
Jacket MaterialPE
Inner Conductor MaterialCopper
Outer Conductor MaterialCorrugated copper

Mechanical specifications

Minimum Bend Radius, multiple Bends254 mm | 10 in
Minimum Bend Radius, Single Bend127 mm | 5 in
Number of Bends, minimum15
Number of Bends, typical30
Tensile Strength159 kg | 350.535 lb
Bending Moment19 N-m | 168.164 in lb
Flat Plate Crush Strength1.3 kg/mm | 72.797 lb/in

Environmental specifications

Installation temperature-40 °C to +60 °C (-40 °F to +140 °F)
Operating Temperature-55 °C to +70 °C (-67 °F to +158 °F)
Storage Temperature-70 °C to +70 °C (-94 °F to +158 °F)
Attenuation, Ambient Temperature20 °C | 68 °F
Average Power, Ambient Temperature40 °C | 104 °F
Average Power, Inner Conductor Temperature100 °C | 212 °F

Packaging and weights

Cable weight0.41 kg/m | 0.276 lb/ft

Regulatory compliance/certifications

AgencyClassification
CENELEC EN 50575 compliant, Declaration of Performance (DoP) available
CHINA-ROHS Below maximum concentration value
ISO 9001:2015Designed, manufactured and/or distributed under this quality management system
ROHSCompliant
UK-ROHSCompliant
REACH-SVHCCompliant as per SVHC revision on www.andrew.com/ProductCompliance